logo REG 6-10




photo symbol


REG 6-10











Order code
REG 6-10
Ports
G1"
Temperature range
max +60°C
Weight
1.8 kg
Inlet pressure range
(p1)
0 ... 16 bar
0 ... 1.6 MPa
Outlet pressure range
(p2)
0.5 ... 10 bar
0.05 ... 1 MPa
Minimum pressure difference
(p1 - p2)
0.2 bar
0.02 MPa
Hysteresis
(p1 = 10 bar / p2 = 0 bar)
0.6
Hysteresis
(p1 = 10 bar / p2 = 8 bar)
0.2
Recommended flow rate
(p = 6 bar a 25 m/s)
5000 Nl/min
Maximum flow rate
(p1 = 10 bar; p2 = 6.3 bar; pressure drop = 1 bar)
13500 Nl/min




Flow characteristics


Flow characteristics




Outlet pressure variation with fluctuating inlet pressure


Outlet pressure variation


Materials
Mounting bracket and manometer are bought separately.